Pig BAFF/CD257(B-Cell Activating Factor) ELISA Kit
ELK8277
Size: Price:
48 T $412.00
96 T $588.00

Overview

Product name: Pig BAFF/CD257(B-Cell Activating Factor) ELISA Kit
Reactivity: Pig
Alternative Names: CD257; TNFSF13B; BLYS; TALL1; THANK; TNFSF20; ZTNF4; B lymphocyte stimulator; Tumor Necrosis Factor Ligand Superfamily Member 13B; Dendritic cell-derived TNF-like; BAFF
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;Tumor immunity;Infection immunity;Immune molecule;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Pig BAFF/CD257. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Pig BAFF/CD257. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Pig BAFF/CD257, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Pig BAFF/CD257 in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
10.00 2.075 1.974
5.00 1.533 1.432
2.50 0.935 0.834
1.25 0.752 0.651
0.63 0.548 0.447
0.32 0.322 0.221
0.16 0.192 0.091
0.00 0.101 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant BAFF/CD257 and the recovery rates were calculated by comparing the measured value to the expected amount of BAFF/CD257 in samples.
Matrix Recovery range Average
serum(n=5) 92-106% 99%
EDTA plasma(n=5) 88-103% 95%
Heparin plasma(n=5) 77-95% 86%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of BAFF/CD257 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 86-92% 95-103% 89-97%
EDTA plasma(n=5) 95-104% 93-105% 82-101% 91-103%
Heparin plasma(n=5) 83-95% 88-102% 85-97% 80-92%