| 48 T | $320.00 |
| 96 T | $458.00 |
| 96 T*5 | $1947.00 |
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 10.00 | 1.955 | 1.887 |
| 5.00 | 1.466 | 1.398 |
| 2.50 | 1.155 | 1.087 |
| 1.25 | 0.795 | 0.727 |
| 0.63 | 0.605 | 0.537 |
| 0.31 | 0.328 | 0.260 |
| 0.16 | 0.239 | 0.171 |
| 0.00 | 0.068 | 0.000 |

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 88-117% | 103% |
| EDTA plasma(n=5) | 92-107% | 100% |
| Heparin plasma(n=5) | 91-100% | 96% |
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 88-95% | 86-116% | 87-109% | 89-97% |
| EDTA plasma(n=5) | 86-109% | 82-107% | 83-97% | 95-106% |
| Heparin plasma(n=5) | 82-115% | 81-94% | 88-98% | 93-118% |