Size: | Price: |
---|---|
48 T | $320.00 |
96 T | $458.00 |
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
10.00 | 1.952 | 1.863 |
5.00 | 1.672 | 1.583 |
2.50 | 1.102 | 1.013 |
1.25 | 0.837 | 0.748 |
0.63 | 0.543 | 0.454 |
0.32 | 0.369 | 0.280 |
0.16 | 0.213 | 0.124 |
0.00 | 0.089 | 0.000 |
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 82-95% | 88% |
EDTA plasma(n=5) | 86-96% | 91% |
Heparin plasma(n=5) | 89-107% | 98% |
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 78-92% | 79-93% | 94-106% | 83-97% |
EDTA plasma(n=5) | 83-97% | 92-103% | 86-97% | 93-101% |
Heparin plasma(n=5) | 87-96% | 86-95% | 91-103% | 87-93% |