| 48 T | $320.00 |
| 96 T | $458.00 |
| 96 T*5 | $1947.00 |
| Concentration (ng/mL) | OD | Corrected OD |
|---|---|---|
| 10.00 | 1.930 | 1.824 |
| 5.00 | 1.590 | 1.484 |
| 2.50 | 1.132 | 1.026 |
| 1.25 | 0.800 | 0.694 |
| 0.63 | 0.529 | 0.423 |
| 0.31 | 0.351 | 0.245 |
| 0.16 | 0.224 | 0.118 |
| 0.00 | 0.106 | 0.000 |

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average |
|---|---|---|
| serum(n=5) | 87-111% | 99% |
| EDTA plasma(n=5) | 94-119% | 107% |
| Heparin plasma(n=5) | 87-104% | 96% |
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
|---|---|---|---|---|
| serum(n=5) | 87-95% | 82-97% | 91-107% | 94-101% |
| EDTA plasma(n=5) | 88-118% | 81-91% | 85-114% | 88-116% |
| Heparin plasma(n=5) | 81-102% | 94-101% | 83-90% | 94-117% |