Size: | Price: |
---|---|
48 T | $320.00 |
96 T | $458.00 |
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
100.00 | 2.402 | 2.298 |
50.00 | 1.709 | 1.605 |
25.00 | 1.384 | 1.280 |
12.50 | 0.975 | 0.871 |
6.25 | 0.573 | 0.469 |
3.13 | 0.313 | 0.209 |
1.57 | 0.186 | 0.082 |
0.00 | 0.104 | 0.000 |
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 82-95% | 88% |
EDTA plasma(n=5) | 95-107% | 101% |
Heparin plasma(n=5) | 84-97% | 91% |
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 83-92% | 91-96% | 85-93% | 95-101% |
EDTA plasma(n=5) | 86-97% | 91-102% | 81-97% | 93-107% |
Heparin plasma(n=5) | 90-99% | 83-97% | 81-103% | 89-101% |