Human DAF(Decay Accelerating Factor) ELISA Kit
ELK2389
Size: Price:
48 T $320.00
96 T $458.00

Overview

Product name: Human DAF(Decay Accelerating Factor) ELISA Kit
Reactivity: Human
Alternative Names: CD55; CR; TC; Complement decay-accelerating factor
Assay Type: Sandwich
Sensitivity: 13.7 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Apoptosis;Immune molecule;
Uniprot ID: P08174
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human DAF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human DAF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human DAF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human DAF in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
2000.00 2.126 2.053
1000.00 1.527 1.454
500.00 1.067 0.994
250.00 0.872 0.799
125.00 0.572 0.499
62.50 0.389 0.316
31.25 0.168 0.095
0.00 0.073 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant DAF and the recovery rates were calculated by comparing the measured value to the expected amount of DAF in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 80-95% 87%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of DAF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 83-96% 87-98% 95-102%
EDTA plasma(n=5) 90-97% 96-102% 91-103% 89-97%
Heparin plasma(n=5) 95-104% 87-96% 92-101% 82-90%