Size: | Price: |
---|---|
48 T | $320.00 |
96 T | $458.00 |
Concentration (ng/mL) | OD | Corrected OD |
---|---|---|
10.00 | 1.985 | 1.896 |
5.00 | 1.563 | 1.474 |
2.50 | 1.146 | 1.057 |
1.25 | 0.752 | 0.663 |
0.63 | 0.427 | 0.338 |
0.32 | 0.326 | 0.237 |
0.16 | 0.196 | 0.107 |
0.00 | 0.089 | 0.000 |
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
Matrix | Recovery range | Average |
---|---|---|
serum(n=5) | 83-95% | 89% |
EDTA plasma(n=5) | 80-97% | 88% |
Heparin plasma(n=5) | 90-105% | 97% |
Matrix | 1:2 | 1:4 | 1:8 | 1:16 |
---|---|---|---|---|
serum(n=5) | 80-92% | 86-102% | 87-103% | 85-101% |
EDTA plasma(n=5) | 85-94% | 90-99% | 95-102% | 82-90% |
Heparin plasma(n=5) | 90-99% | 95-106% | 87-101% | 82-97% |