| 48 T | $412.00 | 
| 96 T | $588.00 | 
| 96 T*5 | $2499.00 | 
| Concentration (ng/mL) | OD | Corrected OD | 
|---|---|---|
| 10.00 | 2.126 | 2.044 | 
| 5.00 | 1.587 | 1.505 | 
| 2.50 | 1.255 | 1.173 | 
| 1.25 | 0.821 | 0.739 | 
| 0.63 | 0.553 | 0.471 | 
| 0.32 | 0.256 | 0.174 | 
| 0.16 | 0.175 | 0.093 | 
| 0.00 | 0.082 | 0.000 | 

Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.
| Matrix | Recovery range | Average | 
|---|---|---|
| serum(n=5) | 83-95% | 89% | 
| EDTA plasma(n=5) | 86-99% | 92% | 
| Heparin plasma(n=5) | 80-95% | 87% | 
| Matrix | 1:2 | 1:4 | 1:8 | 1:16 | 
|---|---|---|---|---|
| serum(n=5) | 95-104% | 82-93% | 81-96% | 83-94% | 
| EDTA plasma(n=5) | 80-92% | 86-102% | 87-103% | 85-101% | 
| Heparin plasma(n=5) | 82-93% | 96-105% | 87-98% | 85-97% |