Products

Human IFNg(Interferon Gamma) ELISA Kit
ELK1036
Size: Price:
48 T $265.00
96 T $376.00

OverviewPublications

Product name: Human IFNg(Interferon Gamma) ELISA Kit
Reactivity: Human
Alternative Names: IFN gamma; IFN-G; IFG; IFI; INFr; IFN; Immune Interferon
Assay Type: Sandwich
Sensitivity: 5.9 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: P01579
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IFNg. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IFNg. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IFNg, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IFNg in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (pg/mL) OD Corrected OD
1000.00 2.128 1.998
500.00 1.482 1.352
250.00 0.896 0.766
125.00 0.543 0.413
62.50 0.306 0.176
31.25 0.251 0.121
15.63 0.222 0.092
0.00 0.130 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant IFNg and the recovery rates were calculated by comparing the measured value to the expected amount of IFNg in samples.
Matrix Recovery range Average
serum(n=5) 96-107% 101%
EDTA plasma(n=5) 87-99% 92%
Heparin plasma(n=5) 84-96% 90%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IFNg and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-103% 87-98% 95-101%
EDTA plasma(n=5) 89-99% 83-95% 98-104% 96-106%
Heparin plasma(n=5) 85-100% 84-98% 95-101% 88-102%