Products

Human COL7(Collagen Type VII) ELISA Kit
ELK3163
Specification: Price:
48 T $320.00
96 T $458.00

OverviewPublications

Product name: Human COL7(Collagen Type VII) ELISA Kit
Reactivity: Human
Alternative Names: COL7-A1; COL7A1; EBD1; EBDCT; EBR1; Long-chain collagen; Epidermolysis Bullosa,Dystrophic,Dominant And Recessive; Collagen Alpha-1(VII)chain
Assay Type: Sandwich
Sensitivity: 6.1 pg/mL
Standard: 1000 pg/mL
Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Developmental science;Nutrition metabolism;Bone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Collagen Type VII(COL7). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Collagen Type VII(COL7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Collagen Type VII(COL7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Collagen Type VII(COL7) in the samples is then determined by comparing the OD of the samples to the standard curve.

Standard curve

Concentration (ng/mL) OD Corrected OD
1000.00 2.027 1.940
500.00 1.609 1.522
250.00 1.186 1.099
125.00 0.861 0.774
62.50 0.456 0.369
31.25 0.387 0.300
15.63 0.232 0.145
0.00 0.087 0.000

Precision

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery

Matrices listed below were spiked with certain level of recombinant COL7 and the recovery rates were calculated by comparing the measured value to the expected amount of COL7 in samples.
Matrix Recovery range Average
serum(n=5) 95-105% 100%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 92-105% 98%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of COL7 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 95-103% 97-105% 88-97%
EDTA plasma(n=5) 83-95% 85-96% 87-101% 83-95%
Heparin plasma(n=5) 98-105% 86-95% 94-103% 95-102%